| ||
| ||
Utilize a friend, or 1 of one's followers to setup a table with your merchandise. It's also a good excuse to obtain new individuals to signal up to your mailing checklist. Following the display, you can even go out entrance and signal a couple of autographs! --------------------------------------------------------------------- PAT Testing Power leads Most contemporary PAT testers have a handy IEC lead check facility. All one needs to do during PAT Testing would be to plug in both ends of the lead and test Earth Continuity, Insulation Resistance and Polarity. The Polarity check just checks that the lead is wired correctly. This could only be done if 1 has use of each sides of the energy cord. On other PAT testers there is a facility to get a 2-stage check of energy leads. The very first stage is really a test of Earth Continuity and Insulation Resistance by plugging each ends with the lead in to the PAT tester. The 2nd stage is a check of the polarity by plugging the power lead into the mains and the other end towards the tester. Couple of lights around the PAT Tester show whether the polarity of the power lead is right or wrong. PAT Testers that don't have this facility can use a energy lead tester that is available being an accessory. This is used inside a 2-stage check. Stage 1: The lead is plugged into the PAT Tester and the lead tester. The test lead is clipped onto a publish provided around the IEC lead tester and also the Earth Continuity and Insulation Resistance test is carried out. Stage 2: The power lead is now plugged into a mains socket as well as into the IEC lead tester. The two lights on the tester display whether or not the polarity of the IEC cable is correct or faulty. When PAT testing lengthy IEC prospects 1 requirements to remember to modify the pass limits as outlined within the IEE Code of Apply. PAT Testing Mains extension leads If a PAT Tester has an IEC lead check facility, then this can be easily adapted to check mains extension prospects as well. All 1 requirements is a brief IEC result in link the socket with the mains lead back again in to the PAT tester as shown. A similar method can also be used if the PAT Tester includes a 2-stage IEC lead check. PAT Testers that don't have an IEC lead check facility at all can use the IEC lead tester. This is utilized inside a 2-stage check as outlined below. Stage 1: The mains lead is plugged in to the PAT Tester and also the brief IEC lead is plugged in to the mains lead and also the IEC lead tester. The check lead is clipped onto a post provided around the IEC lead tester and also the Earth Continuity and Insulation Resistance test is completed. Stage 2: The mains extension lead is now plugged right into a mains socket. The short IEC lead is plugged in to the mains also into the IEC lead tester as proven. The 2 lights around the tester show whether or not the polarity of the mains extension is right or faulty. mains tester
Technorati Tags: earth continuity, earth continuity test, mains tester, pat testing, performing artist, successful, testing earth continuity
Filed under: earth continuity, earth continuity test, mains tester, pat testing, performing artist, successful, testing earth continuity | ||
| Post Comment |
| Entry 1 of 3 |
| Last Page | Next Page |